Product Details:
Payment & Shipping Terms:
|
High Light: | ct current transformer,ct and pt transformers,Current Transformer Analyzer |
---|
Auto Demagnetizes
● | Software-based tool to determine the residual magnetism in current transformers |
● | Analysis of the remanence condition before putting into operation the CT to assure proper function |
● | Simplifies power grid failure analysis after unwanted operation of protective relays |
● | Demagnetizes the CT core after measurement |
PC Control Available
● | Full access to all functions of the KT210 via a PC using the RJ45 interface |
● | Optimizes the integration into automated testing procedures in production lines |
● | Data export into Word |
● | Customizable testing and reports |
Data Handling and Reporting
● | Test reports can be saved on the local host and transferred to a PC |
● | Data and protocols can be shown on a PC via the Word file loader program |
"Guessing" Nameplates(Reference for unknown CT)
● | Determination of unknown CT data |
● | Older CTs can be classified and put into service without contacting the manufacturer |
● | Determinable parameters include: |
CT type | |
Class | |
Ratio | |
Knee point | |
Power Factor | |
Nominal and operating burden | |
Secondary winding resistance |
Technical Features
● | Excellent noise immunity to disturbances from energized power lines close to the measurement |
● | CT ratio and phase measurement with consideration of nominal and connected secondary burden; CT ratio up to 10000:1 |
● | Knee-point voltage from 1 V up to 30 kV can be Measured |
● | Currents from 1% up to 400 % of the rated value |
● | Different burdens (full, ½, ¼, ⅛ burden) |
● | Determination of ALF/ALFi and FS/FSi, Ts, and composite error for nominal and connected burden |
● | CT winding resistance measurement |
● | CT excitation curve (unsaturated and saturated) |
● | Saturation characteristic recording |
● | Direct comparison of excitation curve to a reference curve |
● | CT phase and polarity check |
● | Secondary burden measurement |
● | Automatic demagnetization of the CT after the test |
● | Small and lightweight (< 8 kg) |
● | Short testing time due to fully automatic testing |
● | High level of safety using patented variable frequency method (max. 120 V) |
● | "Nameplate guesser" function for CTs with unknown data |
● | PC control interface |
● | QuickTest: Manual testing interface |
● | Color display readable in bright sunlight |
● | Simulation of measured data with different burdens and currents |
● | Easily adaptable reports (customizable) |
● | Knee-point voltage from 1 V up to 30 kV can be Measured |
● | Automatic assessment according to IEC 60044-1, IEC 60044-6, IEC61869-2, ANSI30/45 |
● | Automatic assessment for accuracy class > 0.1 |
● | Measurement of transient behavior of TPS, TPX, TPY and TPZ type CTs |
● | PT ratio, polarity and excitation curve according to IEC60044-2 |