Brand Name: | Kingsine |
Model Number: | KS813 |
MOQ: | 1 set |
Price: | Negotiation |
Delivery Time: | 15 working days |
Payment Terms: | L/C,T/T |
Source Energy Meter Calibration Equipment
Description Of DC Standard Source Meter Calibrator
Applies to other production and research & development enterprise of energy meter, power distribution terminals, power management, load control, power quality, and medium voltage reactive power compensation.
Feature Of DC Standard Source Power Calibrate
● | Applies to other production and research & development enterprise of energy meter, power distribution terminals, power management, load control, power quality, and medium voltage reactive power compensation. |
● | Open communications protocol to facilitate the secondary development for RTU / FTU / Power Management Terminal / Public variable measuring the terminal factory automatic verification. |
● | Calibrating a variety Analog Digital meter of direct U/I instruments & frequency with DC/AC 0.05% accuracy and the corresponding class digital multimeter for quality inspection, measurement and instrumentation maintenance, parts detection |
● | The calibrating types of test instrument including AC-DC voltage meter, ammeter, single / three phase active and reactive power meter, phase meter, power factor meter, frequency tables, synchronized tables, etc. |
● | The calibrating transducer types are AC-DC voltage transducer, current transducer, single / three phase active and reactive power transmitter, phase transmitter, power factor transducer, frequency transducer, etc. |
● | The calibrating energy meter types as electronic and sensing single-phase, three-phase active and reactive energy meter. |
● | Storage capacity up to 1,000 calibrated meters' data. |
● | 5.4” TFT LCD display, touch pad and rotary encoder control, PC control software also available. |
Specification Of DC Standard Source Transducer Calibrate
Measuring Electrical Energy | |
Measuring Accuracy | 0.1%Rd, PF≥0.5 |
Voltage Range | 100V, 220V, 380V |
Current Range | 0.05~24A |
Distortion of AC Outputs | |
Distortion | <0.2% (non-capacitance load) |
Max Load Capacity of AC Voltage & Current | |
Voltage Output | 25VA max |
Current Output | 25VA max |
Output & Measuring DC voltage | |
Range | 100mV, 1V, 10V, 30V, 100V, 300V, 750V |
Adjustment Range | 0~120%Rg, (0%~110% output range at 750V) |
Resolution | Range x 0.01% |
Accuracy | 0.05%Rg |
Stability | 0.01% / 1min |
Output & Measuring DC current | |
Range | 1mA, 10mA, 100mA, 1A, 5A, 10A, 25A |
Adjustment Range | 0~120%Rg |
Adjustment fineness | Range x 0.01% |
Resolution | Range x 0.01% |
Accuracy | 0.05%Rg |
Stability | 0.01% / 1min |
Max Load Capacity of DC Voltage & Current | |
Voltage Output | 20W max |
Current Output | 25W max |
Power Supply & Environment | |
Ambient Temperature | 22ºC ± 1ºC |
Working Temperature | 0ºC~40ºC, humidity≤85%RH |
Nominal Input Voltage | 115/230Vac appointed, ±10% |
Nominal Frequency | 50/60Hz |
Connection Type | Standard AC socket 60320 |
Weight & Size | |
Dimensions(W x D x H) | 450mm×380mm×190mm |
Weight | 25kg |
Advantage Of DC Standard Source Energy meter calibration
Open protocol for software self-programming.
AC voltage sources: 3x900V@3x25VA, accuracy 0.05%
AC current sources: 3x30A@3x25VA, accuracy 0.05%
3-phase Harmonic Standard Power: 2-31x orders with 0.1 % accuracy
DC voltage sources: 825V@20W max, accuracy 0.05%
DC current sources: 30A@25W max, accuracy 0.05%
FAQ
Q: Can the device test the function of Synchronising or synchronism-check relays?
A: Yes.
Q: How about the guarantee of repair?
A: All of our products have 3-years guarantee of free repair, and life-long maintenance.
Q: What is your technical advantages?
A: Applied to Grid Corporation of measurement testing centers, power companies and power plants measured ministries, national institutions at all levels of measurement tests, also applies to the railway, petroleum, chemical industry, large-scale industrial and mining enterprises and the meter manufacturers, etc.
Brand Name: | Kingsine |
Model Number: | KS813 |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | L/C,T/T |
Source Energy Meter Calibration Equipment
Description Of DC Standard Source Meter Calibrator
Applies to other production and research & development enterprise of energy meter, power distribution terminals, power management, load control, power quality, and medium voltage reactive power compensation.
Feature Of DC Standard Source Power Calibrate
● | Applies to other production and research & development enterprise of energy meter, power distribution terminals, power management, load control, power quality, and medium voltage reactive power compensation. |
● | Open communications protocol to facilitate the secondary development for RTU / FTU / Power Management Terminal / Public variable measuring the terminal factory automatic verification. |
● | Calibrating a variety Analog Digital meter of direct U/I instruments & frequency with DC/AC 0.05% accuracy and the corresponding class digital multimeter for quality inspection, measurement and instrumentation maintenance, parts detection |
● | The calibrating types of test instrument including AC-DC voltage meter, ammeter, single / three phase active and reactive power meter, phase meter, power factor meter, frequency tables, synchronized tables, etc. |
● | The calibrating transducer types are AC-DC voltage transducer, current transducer, single / three phase active and reactive power transmitter, phase transmitter, power factor transducer, frequency transducer, etc. |
● | The calibrating energy meter types as electronic and sensing single-phase, three-phase active and reactive energy meter. |
● | Storage capacity up to 1,000 calibrated meters' data. |
● | 5.4” TFT LCD display, touch pad and rotary encoder control, PC control software also available. |
Specification Of DC Standard Source Transducer Calibrate
Measuring Electrical Energy | |
Measuring Accuracy | 0.1%Rd, PF≥0.5 |
Voltage Range | 100V, 220V, 380V |
Current Range | 0.05~24A |
Distortion of AC Outputs | |
Distortion | <0.2% (non-capacitance load) |
Max Load Capacity of AC Voltage & Current | |
Voltage Output | 25VA max |
Current Output | 25VA max |
Output & Measuring DC voltage | |
Range | 100mV, 1V, 10V, 30V, 100V, 300V, 750V |
Adjustment Range | 0~120%Rg, (0%~110% output range at 750V) |
Resolution | Range x 0.01% |
Accuracy | 0.05%Rg |
Stability | 0.01% / 1min |
Output & Measuring DC current | |
Range | 1mA, 10mA, 100mA, 1A, 5A, 10A, 25A |
Adjustment Range | 0~120%Rg |
Adjustment fineness | Range x 0.01% |
Resolution | Range x 0.01% |
Accuracy | 0.05%Rg |
Stability | 0.01% / 1min |
Max Load Capacity of DC Voltage & Current | |
Voltage Output | 20W max |
Current Output | 25W max |
Power Supply & Environment | |
Ambient Temperature | 22ºC ± 1ºC |
Working Temperature | 0ºC~40ºC, humidity≤85%RH |
Nominal Input Voltage | 115/230Vac appointed, ±10% |
Nominal Frequency | 50/60Hz |
Connection Type | Standard AC socket 60320 |
Weight & Size | |
Dimensions(W x D x H) | 450mm×380mm×190mm |
Weight | 25kg |
Advantage Of DC Standard Source Energy meter calibration
Open protocol for software self-programming.
AC voltage sources: 3x900V@3x25VA, accuracy 0.05%
AC current sources: 3x30A@3x25VA, accuracy 0.05%
3-phase Harmonic Standard Power: 2-31x orders with 0.1 % accuracy
DC voltage sources: 825V@20W max, accuracy 0.05%
DC current sources: 30A@25W max, accuracy 0.05%
FAQ
Q: Can the device test the function of Synchronising or synchronism-check relays?
A: Yes.
Q: How about the guarantee of repair?
A: All of our products have 3-years guarantee of free repair, and life-long maintenance.
Q: What is your technical advantages?
A: Applied to Grid Corporation of measurement testing centers, power companies and power plants measured ministries, national institutions at all levels of measurement tests, also applies to the railway, petroleum, chemical industry, large-scale industrial and mining enterprises and the meter manufacturers, etc.