Brand Name: | KINGSINE |
Model Number: | KF86P |
MOQ: | 1 set |
Price: | negotiation |
Delivery Time: | 15 working days |
Payment Terms: | L/C, T/T |
Basic Functions
The KF86P is a multipurpose, light-weight, field portable test set, it capable of testing a wide variety of electro-mechanical, solid state and microprocessor based protective relays, motor overload relays, IEC61850 testing, and similar protective devices.
● 12 Analog Channels outputs, 6x35A & 6x310V, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics.
● Lightweight, <10Kg, easy carry on flight journey
● The unit can be operated either manually via built-in 9.7" touchscreen and keypad, or placed under full computer control via the KRT software, running on a PC.
● Variable battery simulator, 24~350Vdc, 70Watts max output. Easily supply power for most protection devices.
● Fully function KRT software for test management, graphical test modules, template organized, Xrio/Rio import/export, testing result review, auto result assessment and report generate, etc.
● Transient play back up to 3KHz
● 8x100/1000Mbit Fiber port for IEC61850 SMV and GOOSE simulations
● Inbuilt GPS and IRIG-B synchronized end-to-end testing capability
● 10 binary input, dry contacts or 0-300V potential contacts capability; 4 fast binary outputs isolated each and with <1ms response time.
● Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection
● AC 85~265 / DC 127-350 power supply, World wide range power supply compatibility
● 3-Year free warranty and life-long maintenance
● Free software upgrade
Advance Feature
● Complied IEC61850 edition 1.0 & 2.0 standard
● Transducer calibration
● Energy meter calibration (Mechanical & Electronic meters)
● 10 Low-level analog outputs (8 Voltages + 2 Currents) up to 8V/20mA max.
Specification Of complying IEC61850 sampled value and GOOSE KF86 relay tester
AC current source | |
Amplitude & Power | 6×35A @ 424VA max each; 3×70A @ 670VA max each; |
Accuracy | <0.03%Rd+0.02%Rg Typ. <0.1%Rd+0.05%Rg Guar. |
Range | Range I: 3A Range II: 35A Automatic Range |
DC Offset | <3mA Typ./ <10mA Guar |
Resolution | 1mA |
Distortion | <0.025%Typ. / <0.07% Guar. |
Ascends/Descent response | <100us |
DC Current source | |
Amplitude & Power | 3×20A @ 400W max |
Accuracy | ±5mA @ <1A ±0.2% @ ≥1A |
Ascends/Descent response | <100us |
AC voltage source | |
Amplitude & Power | 6×310V @ 105VA max each |
Accuracy | <0.015%Rd+0.005Rg Typ. <0.04%Rd+0.01Rg Guar. |
Range | Range I: 30V Range II: 310V Automatic Range |
DC Offset | <10mV Typ./ <60mV Guar |
Resolution | 1mV |
Distortion | <0.015%Typ. / <0.05% Guar. |
Ascends/Descent response | <100us |
DC Voltage source | |
Amplitude & Power | 6×350V @ 100W max 3×700V @ 150W max |
Accuracy | ±10mV @ <5V ±0.2% @ ≥5V |
Ascends/Descent response | <100us |
Frequency & Phase Angle | |
Frequency Range | DC ~ 1000Hz, 3000Hz transient |
Frequency Accuracy | ±0.5ppm |
Frequency Resolution | 0.001Hz |
Phase Range | -360°~360° |
Phase Accuracy | <0.02° Typ. / <0.1° Guar. 50/60Hz |
Phase Resolution | 0.001° |
Auxiliary DC Supply (Battery Simulator) | |
Range | 8 ~ 60Vdc (Max Load Current 1.16A) Accuracy<2% 60 ~ 120Vdc (Max Load Current 0.58A) Accuracy<1% 120 ~ 350Vdc (Max Load Current 0.2A) Accuracy<0.5% |
Power | >69W max |
Resolution | 10mV |
Protection | Short-circuit protection |
Overload Protection | Yes |
Isolation | Isolated from other terminal |
Binary input | |
Electrical isolation | 10 pairs of electrical isolated each |
Input impedance | 5 kΩ…13kΩ(Empty contact) |
Input feature | 0 V~300Vdc Or dry contact (Binary 1~4 inputs turn over potential can be programmable) |
Sampling Rate | 10kHz |
Time resolution | 10us |
Time measurement range | infinity |
Time accuracy | ±1ms @ <1s ±0.1% @ ≥1s |
Debounce time | 0~25ms (Software controlled) |
Binary Output | |
Quantity | 4 pairs |
Type | Fast speed transistor, programmable software control |
AC break capacity | Vmax:250V(AC)/ Imax:0.5A |
DC break capacity | Vmax:250V(DC)/ Imax:0.5A |
Electrical isolation | All pairs isolated |
Time Synchronization | |
Satellite synchronization | 1 × SMA,Use for GPS antenna interface Support GPS and Beidou Satellite |
Fiber IRIG-B | 2 × ST,1 for transmission, 1 for receiving |
Electric IRIG-B | 1 × 6Pin 5.08mm phoenix terminal 1 for transmission, 1 for receiving |
External trigger synchronization | 1 × 4Pin 5.08mm phoenix terminal external trigger input + external trigger output |
Sync error | <10us |
Communication interface | |
Ethernet | 2 × RJ45 ,10/100M |
WIFI | Inbuilt WIFI DHCP service |
Serial port | 1 × RS232 |
USB | 2 × USB2 |
Weight & Size | |
Size | 390mm×256mm×140mm |
Weight | 10kg |
Display | 9.7inch LCD, touch screen |
Keypad | Number key + direction key |
Power supply | |
Nominal voltage | 220V/110V (AC) |
Allowable voltage | 85 - 265 VAC ;127V~350V(DC) |
Nominal Frequency | 50Hz |
Allowable Frequency | 47-63Hz |
Current | 10A max |
Power Consumption | 1200VA max |
Connection Type | Standard AC socket 60320 |
Working environment | |
Operating temperature | -10~+55 ℃ |
Relative humidity | 5~95%,Non-condensation |
Storage temperature | -20℃ ~ +70℃ |
Atmospheric pressure | 80kPa~110 kPa(altitude 2000m or lower) |
(Optional modules)
IEC61850 functions:
● | Fully complying IEC61850 Sampling value and GOOSE; (IEC61850-9-1, IEC61850-9-2/(LE), IEC60044-7/8) |
● | Able to simultaneously output sampling value and analog signals, or subscriber and publish GOOSE message and relay contact binary I/O function. |
● | Up to 36 sampling value channels can be mapped. |
Fiber port (LC type) | |
Type | 100Base-FX (100Mbit,Fiber, full duplex) |
Port Number | 8 Pairs |
Cable model | 62.5/125μm(Multiple-mode fiber, orange) |
Wave length | 1310nm |
Transmission distance | > 1Km |
Status indication | SPD Green (lights): active connection LinkAcT Yellow (blinking): data exchange |
10 Low-Level channels signal output function:
Low-level signal output | |
Output channels | 10 channels, 8 Voltage outputs + 2 Current outputs |
Output port type | Phoenix terminal |
Output range | 8x0~8Vrms; 2x0~20mA |
Accuracy | (0.01~0.8 Vrms/0~2mA):<0.05% Typ. / <0.1% Guar. (0.8~8 Vrms/2~20mA): <0.02% Typ. / <0.05% Guar. |
Resolution | 250µV |
Harmonic(THD%) | < 0.05% Typ. / <0.1% Guar. |
Frequency range | DC~1.0kHz, transient 3KHz |
Frequency accuracy | 0.002%(Normal frequency) |
Frequency resolution | 0.001Hz |
Phase range | 0~359.9° |
Phase accuracy | <0.02°,50/60Hz |
Phase resolution | ±0.001° |
Transducer Calibration Function:
DC Measurement Input | ||
Voltage Input | Range | 0~±10V dc |
Max Input | ±11V dc | |
Accuracy | Accuracy <0.05% rg Typ. <0.02% rg Guar. | |
Input Impedance | 1M ohm | |
Current Input | Range | 0~±1mA / 1~±20mA, auto range |
Max Input | 600mA | |
Accuracy | Accuracy <0.05% rg Typ. <0.02% rg Guar. | |
Input Impedance | 15 ohm |
Energy Meter Calibration Function:
Energy Meter Calibration | |
Sensor Usage | Mechanical meters / Electronic meters |
Sensor Output | High lever:>4.5V, Low level:<0.2V |
Pulse Input | 1 pulse input port, 5Vdc high level valid only. |
Pulse Range | 500KHz pulse input Max. |
Pulse Output | 1 Transistor output, Open-collector, 5Vdc/5mA |
Inquiry us for more details.
F&A
Q: 1. What's your acceptable payment term?
A: T/T and L/C at sight are our normal acceptable payment terms.
Q: 2.How long is the warranty period?
A:We provide 3-years guarantee of free repair and life-long maintenance.
Q: 3.Why do we offer a three-year warranty?
A:First of all,The quality goal of KINGSINE company is that no quality failure occurs within five years of customer use.
The second,KINGSINE has been engaged in the overseas market for 12 years.Up to now,about 12000 sets of equipment have been running in 80 countries,and the annual failure rate is less than 1%.
The third,Our products are modular design,If there is a fault,it can be remote fault diagnosis,and then express products’ parts to customer for quick repair.
About US:
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable. Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.
Brand Name: | KINGSINE |
Model Number: | KF86P |
MOQ: | 1 set |
Price: | negotiation |
Payment Terms: | L/C, T/T |
Basic Functions
The KF86P is a multipurpose, light-weight, field portable test set, it capable of testing a wide variety of electro-mechanical, solid state and microprocessor based protective relays, motor overload relays, IEC61850 testing, and similar protective devices.
● 12 Analog Channels outputs, 6x35A & 6x310V, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics.
● Lightweight, <10Kg, easy carry on flight journey
● The unit can be operated either manually via built-in 9.7" touchscreen and keypad, or placed under full computer control via the KRT software, running on a PC.
● Variable battery simulator, 24~350Vdc, 70Watts max output. Easily supply power for most protection devices.
● Fully function KRT software for test management, graphical test modules, template organized, Xrio/Rio import/export, testing result review, auto result assessment and report generate, etc.
● Transient play back up to 3KHz
● 8x100/1000Mbit Fiber port for IEC61850 SMV and GOOSE simulations
● Inbuilt GPS and IRIG-B synchronized end-to-end testing capability
● 10 binary input, dry contacts or 0-300V potential contacts capability; 4 fast binary outputs isolated each and with <1ms response time.
● Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection
● AC 85~265 / DC 127-350 power supply, World wide range power supply compatibility
● 3-Year free warranty and life-long maintenance
● Free software upgrade
Advance Feature
● Complied IEC61850 edition 1.0 & 2.0 standard
● Transducer calibration
● Energy meter calibration (Mechanical & Electronic meters)
● 10 Low-level analog outputs (8 Voltages + 2 Currents) up to 8V/20mA max.
Specification Of complying IEC61850 sampled value and GOOSE KF86 relay tester
AC current source | |
Amplitude & Power | 6×35A @ 424VA max each; 3×70A @ 670VA max each; |
Accuracy | <0.03%Rd+0.02%Rg Typ. <0.1%Rd+0.05%Rg Guar. |
Range | Range I: 3A Range II: 35A Automatic Range |
DC Offset | <3mA Typ./ <10mA Guar |
Resolution | 1mA |
Distortion | <0.025%Typ. / <0.07% Guar. |
Ascends/Descent response | <100us |
DC Current source | |
Amplitude & Power | 3×20A @ 400W max |
Accuracy | ±5mA @ <1A ±0.2% @ ≥1A |
Ascends/Descent response | <100us |
AC voltage source | |
Amplitude & Power | 6×310V @ 105VA max each |
Accuracy | <0.015%Rd+0.005Rg Typ. <0.04%Rd+0.01Rg Guar. |
Range | Range I: 30V Range II: 310V Automatic Range |
DC Offset | <10mV Typ./ <60mV Guar |
Resolution | 1mV |
Distortion | <0.015%Typ. / <0.05% Guar. |
Ascends/Descent response | <100us |
DC Voltage source | |
Amplitude & Power | 6×350V @ 100W max 3×700V @ 150W max |
Accuracy | ±10mV @ <5V ±0.2% @ ≥5V |
Ascends/Descent response | <100us |
Frequency & Phase Angle | |
Frequency Range | DC ~ 1000Hz, 3000Hz transient |
Frequency Accuracy | ±0.5ppm |
Frequency Resolution | 0.001Hz |
Phase Range | -360°~360° |
Phase Accuracy | <0.02° Typ. / <0.1° Guar. 50/60Hz |
Phase Resolution | 0.001° |
Auxiliary DC Supply (Battery Simulator) | |
Range | 8 ~ 60Vdc (Max Load Current 1.16A) Accuracy<2% 60 ~ 120Vdc (Max Load Current 0.58A) Accuracy<1% 120 ~ 350Vdc (Max Load Current 0.2A) Accuracy<0.5% |
Power | >69W max |
Resolution | 10mV |
Protection | Short-circuit protection |
Overload Protection | Yes |
Isolation | Isolated from other terminal |
Binary input | |
Electrical isolation | 10 pairs of electrical isolated each |
Input impedance | 5 kΩ…13kΩ(Empty contact) |
Input feature | 0 V~300Vdc Or dry contact (Binary 1~4 inputs turn over potential can be programmable) |
Sampling Rate | 10kHz |
Time resolution | 10us |
Time measurement range | infinity |
Time accuracy | ±1ms @ <1s ±0.1% @ ≥1s |
Debounce time | 0~25ms (Software controlled) |
Binary Output | |
Quantity | 4 pairs |
Type | Fast speed transistor, programmable software control |
AC break capacity | Vmax:250V(AC)/ Imax:0.5A |
DC break capacity | Vmax:250V(DC)/ Imax:0.5A |
Electrical isolation | All pairs isolated |
Time Synchronization | |
Satellite synchronization | 1 × SMA,Use for GPS antenna interface Support GPS and Beidou Satellite |
Fiber IRIG-B | 2 × ST,1 for transmission, 1 for receiving |
Electric IRIG-B | 1 × 6Pin 5.08mm phoenix terminal 1 for transmission, 1 for receiving |
External trigger synchronization | 1 × 4Pin 5.08mm phoenix terminal external trigger input + external trigger output |
Sync error | <10us |
Communication interface | |
Ethernet | 2 × RJ45 ,10/100M |
WIFI | Inbuilt WIFI DHCP service |
Serial port | 1 × RS232 |
USB | 2 × USB2 |
Weight & Size | |
Size | 390mm×256mm×140mm |
Weight | 10kg |
Display | 9.7inch LCD, touch screen |
Keypad | Number key + direction key |
Power supply | |
Nominal voltage | 220V/110V (AC) |
Allowable voltage | 85 - 265 VAC ;127V~350V(DC) |
Nominal Frequency | 50Hz |
Allowable Frequency | 47-63Hz |
Current | 10A max |
Power Consumption | 1200VA max |
Connection Type | Standard AC socket 60320 |
Working environment | |
Operating temperature | -10~+55 ℃ |
Relative humidity | 5~95%,Non-condensation |
Storage temperature | -20℃ ~ +70℃ |
Atmospheric pressure | 80kPa~110 kPa(altitude 2000m or lower) |
(Optional modules)
IEC61850 functions:
● | Fully complying IEC61850 Sampling value and GOOSE; (IEC61850-9-1, IEC61850-9-2/(LE), IEC60044-7/8) |
● | Able to simultaneously output sampling value and analog signals, or subscriber and publish GOOSE message and relay contact binary I/O function. |
● | Up to 36 sampling value channels can be mapped. |
Fiber port (LC type) | |
Type | 100Base-FX (100Mbit,Fiber, full duplex) |
Port Number | 8 Pairs |
Cable model | 62.5/125μm(Multiple-mode fiber, orange) |
Wave length | 1310nm |
Transmission distance | > 1Km |
Status indication | SPD Green (lights): active connection LinkAcT Yellow (blinking): data exchange |
10 Low-Level channels signal output function:
Low-level signal output | |
Output channels | 10 channels, 8 Voltage outputs + 2 Current outputs |
Output port type | Phoenix terminal |
Output range | 8x0~8Vrms; 2x0~20mA |
Accuracy | (0.01~0.8 Vrms/0~2mA):<0.05% Typ. / <0.1% Guar. (0.8~8 Vrms/2~20mA): <0.02% Typ. / <0.05% Guar. |
Resolution | 250µV |
Harmonic(THD%) | < 0.05% Typ. / <0.1% Guar. |
Frequency range | DC~1.0kHz, transient 3KHz |
Frequency accuracy | 0.002%(Normal frequency) |
Frequency resolution | 0.001Hz |
Phase range | 0~359.9° |
Phase accuracy | <0.02°,50/60Hz |
Phase resolution | ±0.001° |
Transducer Calibration Function:
DC Measurement Input | ||
Voltage Input | Range | 0~±10V dc |
Max Input | ±11V dc | |
Accuracy | Accuracy <0.05% rg Typ. <0.02% rg Guar. | |
Input Impedance | 1M ohm | |
Current Input | Range | 0~±1mA / 1~±20mA, auto range |
Max Input | 600mA | |
Accuracy | Accuracy <0.05% rg Typ. <0.02% rg Guar. | |
Input Impedance | 15 ohm |
Energy Meter Calibration Function:
Energy Meter Calibration | |
Sensor Usage | Mechanical meters / Electronic meters |
Sensor Output | High lever:>4.5V, Low level:<0.2V |
Pulse Input | 1 pulse input port, 5Vdc high level valid only. |
Pulse Range | 500KHz pulse input Max. |
Pulse Output | 1 Transistor output, Open-collector, 5Vdc/5mA |
Inquiry us for more details.
F&A
Q: 1. What's your acceptable payment term?
A: T/T and L/C at sight are our normal acceptable payment terms.
Q: 2.How long is the warranty period?
A:We provide 3-years guarantee of free repair and life-long maintenance.
Q: 3.Why do we offer a three-year warranty?
A:First of all,The quality goal of KINGSINE company is that no quality failure occurs within five years of customer use.
The second,KINGSINE has been engaged in the overseas market for 12 years.Up to now,about 12000 sets of equipment have been running in 80 countries,and the annual failure rate is less than 1%.
The third,Our products are modular design,If there is a fault,it can be remote fault diagnosis,and then express products’ parts to customer for quick repair.
About US:
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable. Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.