Product Details:
Place of Origin: SHENZHEN,CHINA
Brand Name: KINGSINE
Certification: ISO9001:2008
Model Number: KS-3000
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Delivery Time: 15DAYS
Payment Terms: T/T
Detailed Product Description
High Light:

PMC200 Power Monitoring System Software

,

Event Logging Power Monitoring System Software

PMC200 Power Monitoring System Software For Alarm & Event Logging

Data recording and statistical analysis
Various reports and curves issuing
Multilevel user rights management
Remote O/C operation of circuit breakers

Main Functions

 Distribution system operation monitoring;

 Power quality monitoring and analysis;

 Energy consumption analysis in statistics;

 Alarm and event logging;

 History operating trend curve and reports suchlike tailored functional software modules;

 User Management.

 Overview     

      At present, the trend and reliability of the industry of power supply and distribution plays an important role in the development of nation economy.

     With sharp increasing number for major fiscal-aid projects, landmark buildings / large public facilities across the country,  users who demand multi-substations in large area also expect higher standard for power supply and distribution system in the aspects of reliability, security, real-time performance, ease of use, compatibility and minimization of the side-affect of fault scope. Based on remote monitoring, field bus, computer integrated management technology, LV intelligent power distribution system start spread as a standardized configuration in many areas in many industry.

    With the help of computers, communications equipment, measurement and control unit, the protection relays, KS-3000 power monitoring system software provides users with the base platform for real-time data acquisition of system, switch status detection and remote control. KS-3000 system can provide users with monitoring integration “as the overall solution”, including real-time power collection modules, energy management analysis module, real-time history database, event alarm module, short message alarm module. 

   KS-3000 power monitoring system software play an important role in the line of power utility systems, commercial and public buildings, infrastructure, automobile, petrochemical, telecommunications, metallurgy, light industry, water treatment and other fields, and it results in good energy management.

 Product Value

  • To improve the reliability of the distribution system operation, and to ensure the continuity of power supply;
  • To improve the efficiency of the distribution system operation and to save operating cost;
  • To improve power consumption, and to promote energy saving and environmental protection;
  • Able to provide effective fault diagnosis, shorten the recovery time.

Master Layer (Computers and software)
      Station control layer consist of KS-3000 power monitoring software, monitoring Host device, database release server,
Printer, UPS power; depending on the different environment, it can do in two ways:One server, One client and one server, multiple clients.

Communication Layer (Correspondence Device) 

    Layer consist of industrial switchboard and communication management device,so it can realize the connection between the on-site monitoring & control device and the monitoring host device, complex systems also adopt Fiber circle-net redundancy structure.

 Interval Layer

   To finish field measurement & monitoring & communication etc functions, it is Interval layer installation where installed with KS610 power quality monitoring devices, PMC Series Intelligent Instruments, protection relays, transformers temperature controller device.PMC series meter includes PMC200 Power Data Measurement and Control Meter, PMC180 three-phase digital number displaying meter, PMC180N, three-phase power network meter, PMC100 single phase digital power meter, and PMC100N single phase power network meter.

Typical Solution

Economical Solution 

Scheme Benefit

  • Electric parameter of Real-time monitoring power system;
  • Data record and statistics analysis;
  • Creation of various report and curve;
  • Summary of inward-wire energy consumption;
  • Low cost for system build, economical solution.

Solution Systematic Configuration

  • Adopt PMC180Z for inward-wire cabin and communication cabin, Realize inward-wire full electric monitoring & harmonic monitoring on current/voltage;
  • Feeder circuits using PMC180P, PMC18OI and PMC100I, Able to do feeder circuit current monitoring and power monitoring;
  • The main station is equipped with a monitoring host and KS-3000 power monitoring system, Software for power system real-time data monitoring, energy statistics, Generate various reports.

Project Feature

Small investment but get power system monitoring, Economical and practical.

Standard Solution

Program Realization:

  • Power system real-time running state and parameters monitoring;
  • Data recording and statistical analysis;
  • Various reports and curves issuing;
  • Power consumption Statistic of lead-in and main feeder line;
  • Multilevel user rights management;
  • Remote O/C operation of circuit breakers.

System Configuration:

  • PMC200 in Incoming cabinet and Tie-cabinet;
  • Full monitoring of the lead-in power, voltage, current and harmonics;
  • Load demand statistics & SOE event log, & multi-rate watt-hour accumulated;
  • Feeder circuit using PMC18OZ/PMC18OI/PMC100I;
  • Full power/voltage/current/harmonics monitoring and electric energy accumulated to main feeder circuit;
  • Current monitoring to normal feeder loop;
  • Monitoring computer and KS-3000 power monitoring system Software in master station, to realize the real-time data monitoring, power system harmonic analysis, electric energy statistics, Event alarm and the short message alarm and various reports.

Project Features:

    Full power monitoring, analysis, control O/C switch of electric power system, real-time short-letter alarm and high performance cost ratio.

Power Quality Solution

Program Realization:

  • Real-time Monitoring of power system running state and parameters;
  • Power quality real-time monitoring of transformer lead-in;
  • Real-time voltage and current waveform display;
  • Fault recording and playback;
  • Data recording and statistical analysis;
  • Variety of reports and curves saving;
  • Lead-in and main feeder power consumption Statistic;
  • Multilevel user rights management;
  • Breakers Remote O/C operation.

System Configuration:

  • KS610 power quality on-line monitoring the Transformer lead-in, to achieve comprehensive power quality on-line monitoring, analysis of the 10KV line;
  • PMC200 in Incoming cabinet and Tie-cabinet for lead-in power/voltage/current/harmonics monitoring, Load demand statistics, SOE event log, multi-rate watt-hour accumulated;
  • PMC200/PMC18OZ/PMC10OZ in Feeder loop for full power/voltage/current/harmonic monitoring and energy accumulation of the feeder loop;
  • Monitoring computer and KS-3000 power monitoring system Software in The master station, to implement the comprehensive power quality on-line monitoring, analysis, real-time data monitoring, harmonic analysis, and electric energy statistics of power system, event alarm and SMS alarm with various reports.

Project Features:

   Real-time power quality monitoring and analysis, analysis of the whole power monitoring, control, closing. Fault recording and playback of electric power system for easy fault analyze;Real-time SMS alarm; High performance cost ratio.

System Function

System Operation Monitoring & Control

   Power standard graphics mode for the whole system structure reflection; Dynamic refresh to real-time operating parameters and equipment operation state of each line; Remote control supportable for flexible customerized configuration.

Power Quality Monitoring Analysis

    The system power quality continuous monitoring for the real-time monitoring of system voltage flicker, transient, imbalance, frequency deviation, harmonics and other power quality problems; especially event trigger waveform capture and the disturbance waveforms record for easy power quality analysis and fault analysis.

Energy Consumption Statistics & Analysis

    Adopt consolidated statements way, real-time display, statistical record of each line and each period electricity consumption which include date, month, year and cross-time statistical statements, describe each line each period electricity consumption drift by curve, analyses for energy consumption, it also can be saved, printed, query and import browser.

Alarm and Event Management

  System alarm include: line load over capability, measured value over limited, equipment state change; Alarm condition user can be configured manually according to the actual situation; In the real-time store data library of Alarm and event message, store capability is only restricted by hardware volume; Alarm and event message sort and merge query by time, type, alarm group etc;Alarm message can use the way of Email, cell phone message, sound, or text to inform relevant personnel.

Report Management

    System adopts template to build a statement, it also can customized template, system update statement data regularly via template demand.

    System support statement file saved as format of rtl, xls, csv for data secondary development.

History Data Management

    System store important data to history data library, it can be queried by time quantum and curve the graph.

User Management

  Ensure that system security run steadily; user authority management can prevent unauthorized operation. Define different level user logic name, password and operation authority, provide credible and safe guarantee for system operation and maintain management.

Web Message System

Based on IE browser data visit function, Web display picture and data will be synchronously as serve, check real-time data view, real-time curve view, history data view, history curve view, data library view, data library time curve view and monitor pictures.

Network Interconnection

    Support industry OPC interface, it can be OPC serve for other program to provide data (such as DCS system); it also can be OPC client terminal, get data from other system. System can support access from multiple of third-party equipment.

 