Product Details:
Payment & Shipping Terms:
|
High Light: | Automation Protection Relay Testing K68i,6.4'' LCD Display Protection Relay Testing |
---|
Automation Protection Relay Testing K68i , Single Phase
All-in-one design relay tester with 6.4 inches LCD display
Binary Inputs Number: 8 pairs
Binary output Number :4 pairs
With all in one design, able to test most of relays by manual or automation!
Software Features:
1. Able to test most of Relays by manual or automation: Voltage relays, Current relays, Frequency relays,
Power relays, Impedance relays, Harmonic relays, Distance relays etc;
2. With self housing-grounding-detecting function, the software interface can show whether the housing
well grounding or not, effectively ensure the safety of testing.
Hardware Features:
1. All-in-one design relay tester with 6.4 inches LCD display;
2. 4 Phase AC Voltage Sauce and 3 phase AC current source can be output together, even the Range,
Phase, Frequency can be set independently;
3. Max AC voltage can reach 300V each phase, Offer independent Aux. DC to tested devices, 0 ~ 300
V/0.6A (Poleless and adjustable);
4. Offer different type of computer port: USB port, RJ45 port, VGA Video Port , USB / RJ45 ports
convenient for data transfer, VGA Video Port can connect to projector and easy for study and training;
5. Super long life Rotary encoder + Functional keyboard.
Technical Data of K68
Voltage generators |
||
Setting Range |
4-phase AC (L-N) |
4 x 0 ... 300V |
|
2-phase AC (L-L) |
2x 0 ...600 V |
Power |
4-phase AC (L-N) |
4 x110VA, at 0 ...300 V |
|
2-phase AC (L-L) |
2 x 220VA, at 0 ...600 V |
Accuracy |
<0.07% reading + 0.03% range guaranteed at 0-300V <0.04% reading + 0.01% range typical at 0-300V |
|
Resolution |
1mV |
|
Current generators |
||
Setting Range |
3-phase AC (L-N) |
3 x 0 ... 35 A |
|
1-phase AC (3L-N) |
1 x 0 ...105 A |
Power |
3-phase AC (L-N) |
1x 450VA, at 0 ... 35A |
|
1-phase AC (3L-N) |
1 x 1000VA, at 0 ...105A |
Accuracy |
<0.14% reading + 0.06% range guaranteed at 0-35A <0.05% reading + 0.02% range typical at 0-35A |
|
Resolution |
1mA |
|
Generators, general |
||
Frequency |
Range |
0 ... 1000 Hz |
|
Accuracy / drift |
Error < 0.001Hz at 10 ... 65Hz, Error < 0.01Hz at 65Hz...450Hz Error < 0.02Hz at 450Hz...1000Hz |
|
Resolution |
0.001Hz |
Phase |
Range |
- 360° ... +360° |
|
Accuracy / drift |
Error < 0.2 ° |
|
Resolution |
0.1° |
Time |
Range |
0 ... 999, 999.999s |
|
Accuracy / drift |
Error<1ms |
DC generators |
||
Voltage ranges |
0 ... 300V/180VA |
|
Current ranges |
0 ... 20A/300W |
|
Accuracy |
Error<0.1% reading + 0.1% range guaranteed at 0…300 V; Error <0.1% reading + 0.1% range guaranteed at 0...20 A; |
|
Resolution |
1mA; 1 mV |
|
Aux DC Supply |
||
Range |
0...300V/0.6A |
|
Binary inputs |
||
Number |
8 pairs |
|
Compatible Voltage |
10V ... 250V DC |
|
Binary outputs |
||
Number |
4 Pairs |
|
Capacity |
250V/3A (AC/DC) |
|
Synchronization |
||
Synchronization mode |
GPS |
|
Harmonic |
||
Harmonic overlap times |
2 ... 9 times |
|
Power supply |
||
Nominal input voltage |
220V±20% VAC, 1-phase |
|
Power |
1000VA |
|
Nominal frequency |
50±10% Hz |
|
Environmental conditions |
||
Operation temperature |
-5°C ... 55 °C |
|
Storage temperature |
-20°C ... 75 °C |
|
Humidity range |
5% ... 90 %, non-condensing |
|
Weight |
20KG |
|
Dimensions |
460(D)×140 (W)×360 (H) mm |
|
Interface |
RJ45 , USB, VGA |
Main Series Relay Tester List:
K68 series |
K68 |
3x35A, 4x130V, 5 function modules, Ethernet, TFT LCD, WinCE |
K68i |
3x35A, 4x300V, 5 function modules, Ethernet, TFT LCD, WinCE |
Major Functions:
Items |
IEEE(R) No. |
Overcurrent relays |
50/76 |
Inverse time overcurrent relays |
51 |
Undercurrent relays |
37 |
Ground fault relays |
50 |
Directional overcurrent relays |
67 |
Directional ground fault relays |
67N |
Overvoltage relays |
59 |
Undervoltage relays |
27 |
Directional voltage relays |
91 |
Directional power relays |
32 |
Power factor relays |
55 |
Distance protection equipment (phase by phase) |
21 |
Automatic reclosing devices |
79 |
Tripping relays |
94 |
Voltage regulating relays |
|
Overimpedance relays, Z> |
|
Underimpedance relays, Z |
|
Time-delay relays |
|
Contact Person: Amy