Product Details:
Payment & Shipping Terms:
|
High Light: | Protection Relay Testing K1066,8 Pairs Binary Input protective relay tester,6.4 LCD Screen Protection Relay Testing |
---|
6.4 LCD Screen Protection Relay Testing K1066 , 8 Pairs Binary Input
Binary Inputs Number: 8 pairs
Compatible Voltage:10V - 250V DC
In house and field test, Laptop is unnecessary
1. Adopts 6.4 large LCD screen, and provided with VGA video interface, making it available to connect to
projector for training;
2. With alarm function of housing grounding testing and external voltage input, to guaranty personal
security;
3. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A(Poleless and adjustable);
4. Two in one of meter and source, with function of both internal and external testing, self-calibration,
oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Function of transducer and energy meter testing (optional function);
6. Adopt Smart and stable Window CE embedded system. Windows has the advantage of small
application program with fast speed, which overcomes the problem of bad stability, easy-damage
hardware, and virus of Windows 98/2000/XP;
7. Use high-speed CF card as the storage, more stable, anti-shock compared with ordinary hardware, so
works more reliable.
Main specifications:
Voltage generators |
||
Setting Range |
7-phase AC (L-N) |
7 x 0 ... 130 V |
2-phase AC (L-L) |
2 x 0 ... 260 V |
|
Power |
7-phase AC (L-N) |
7 x 70VA, at 0 ... 130 V |
2-phase AC (L-L) |
1 x 140VA, at 0 ... 260 V |
|
Accuracy |
<0.07% reading + 0.03% range guaranteed at 0-130V <0.04% reading + 0.01% range typical at 0-130V |
|
Resolution |
1mV |
|
Current generators |
||
Setting Range |
6-phase AC (L-N) |
6 x 0 ... 20 A |
3-phase AC (2L-N) |
3 x 0 ... 40 A (Group A II B) |
|
1-phase AC (6L-N) |
1 x 0 ... 120 A |
|
Power |
6-phase AC (L-N) |
6 x 150 VA , at 0 ... 20A Max 250VA, with the other current channels unload |
3-phase AC (2L-N) |
3 x 300VA, at 0 ... 40A (Group A II B) Max 450VA, with the other current channels unload |
|
1-phase AC (6L-N) |
1 x 900 VA |
|
Accuracy |
<0.14% reading + 0.06% range guaranteed at 0-40A <0.05% reading + 0.02% range typical at 0-40A |
|
Resolution |
1mA |
|
Generators, general |
||
Frequency |
Range |
0 ... 1000 Hz |
Accuracy / drift |
Error < 0.001Hz at 10 ... 65Hz, Error < 0.01Hz at 65Hz...450Hz Error < 0.02Hz at 450Hz...1000Hz |
|
Resolution |
0.001Hz |
|
Phase |
Range |
- 360° ... +360° |
Accuracy / drift |
Error < 0.2 ° |
|
Resolution |
0.1° |
|
Time |
Range |
0 ... 999, 999.999s |
Accuracy / drift |
Error<0.1ms |
|
Resolution |
1ms |
|
DC generators |
||
Voltage ranges |
0 ... 300V/180VA |
|
Current ranges |
0 ... 20A/300W |
|
Accuracy |
Error<0.1% reading + 0.1% range guaranteed at 0...300 V; Error <0.1% reading + 0.1% range guaranteed at 0...20 A; |
|
Resolution |
1mA; 1 mV |
|
Harmonic |
|
|
Harmonic superpose times |
2 ... 20 |
|
Aux DC Supply |
||
Range |
0...250V/0.6A |
|
Binary Inputs |
||
Number |
8 pairs |
|
Compatible Voltage |
10V ... 250V DC |
|
Binary outputs |
||
Number |
4 Pairs |
|
Capacity |
250V/3A AC/DC |
|
Synchronization |
||
Synchronization mode |
GPS |
|
Power supply |
||
Nominal input voltage |
220V±10% VAC, 1-phase |
|
Power |
1000VA |
|
Nominal frequency |
50±10% Hz |
|
Environmental conditions |
||
Operation temperature |
-5°C ...55 °C |
|
Storage temperature |
-20°C ...75 °C |
|
Humidity range |
5 ... 90 %, non-condensing |
|
Weight |
20KG |
|
Dimensions |
460(D)×140 (W)×360 (H) mm |
|
Interface |
RJ45 , USB, RS232, PS/2, VGA |
|
PC Connection |
RJ45 |
K10 Series Protection Relay Test Set:
Model |
Channels |
AC Outputs |
K1063i |
10 output channels |
6*30A/3*60A/4*300V |
K1066i |
13 output channels |
6*30A/3*60A/7*300V |
K1066 |
13 output channels |
6*20A/3*40A/7*130V |
K1066+ |
13 output channels, |
6*30A/3*60A/7*130V |
K1063 |
10 output channels |
6*20A/3*40A/4*130V |
K1036 |
10 output channels |
3*40A/7*130V |
K1040 |
7 output channels |
3*40A/4*130V |
K1030 |
7 output channels |
3*30A/4*130V |
Contact Person: Amy
Tel: +8613603051120