Product Details:
Payment & Shipping Terms:
|
High Light: | Secondary Injection Test Set K68i,Injection test relay server |
---|
Protection Relay Secondary Injection Test Set K68i
1. Easy test
2. Operation menu, Simple operation
3. Power:1000VA
4. With self housing-grounding detecting function
5. Max AC voltage can reach 300V each phase
6. All-in-one design relay tester with 6.4 inches LCD display
The most-effective solution for relay testing!
With all in one design, able to test most of Relays by manual or automation!
Software Features
1. Able to test most of Relays by manual or automation: Voltage relays, Current relays, Frequency relays,
Power relays, Impedance relays, Harmonic relays, Distance relays etc;
2. With self housing-grounding-detecting function, the software interface can show whether the housing
well grounding or not, effectively ensure the safety of testing.
Hardware Features
1. All-in-one design relay tester with 6.4 inches LCD display;
2. 4 Phase AC Voltage Sauce and 3-phase AC current sauce can be output together, even the Range,
Phase, Frequency can be set independently;
3. Max AC voltage can reach 300V each phase, Offer independent Aux. DC to tested devices, 0 ~ 300
V/0.6A (Poleless and adjustable);
4. Offer different type of computer port: USB port, RJ45 port, VGA Video Port , USB / RJ45 ports
convenient for data transfer, VGA Video Port can connect to projector and easy for study and training;
5. Super long life Rotary encoder + Functional keyboard.
Technical Data of K68
Voltage generators |
||
Setting Range |
4-phase AC (L-N) |
4 x 0 ... 300V |
|
2-phase AC (L-L) |
2x 0 ...600 V |
Power |
4-phase AC (L-N) |
4 x110VA, at 0 ...300 V |
|
2-phase AC (L-L) |
2 x 220VA, at 0 ...600 V |
Accuracy |
<0.07% reading + 0.03% range guaranteed at 0-300V <0.04% reading + 0.01% range typical at 0-300V |
|
Resolution |
1mV |
|
Current generators |
||
Setting Range |
3-phase AC (L-N) |
3 x 0 ... 35 A |
|
1-phase AC (3L-N) |
1 x 0 ...105 A |
Power |
3-phase AC (L-N) |
1x 450VA, at 0 ... 35A |
|
1-phase AC (3L-N) |
1 x 1000VA, at 0 ...105A |
Accuracy |
<0.14% reading + 0.06% range guaranteed at 0-35A <0.05% reading + 0.02% range typical at 0-35A |
|
Resolution |
1mA |
|
Generators, general |
||
Frequency |
Range |
0 ... 1000 Hz |
|
Accuracy / drift |
Error < 0.001Hz at 10 ... 65Hz, Error < 0.01Hz at 65Hz...450Hz Error < 0.02Hz at 450Hz...1000Hz |
|
Resolution |
0.001Hz |
Phase |
Range |
- 360° ... +360° |
|
Accuracy / drift |
Error < 0.2 ° |
|
Resolution |
0.1° |
Time |
Range |
0 ... 999, 999.999s |
|
Accuracy / drift |
Error<1ms |
DC generators |
||
Voltage ranges |
0 ... 300V/180VA |
|
Current ranges |
0 ... 20A/300W |
|
Accuracy |
Error<0.1% reading + 0.1% range guaranteed at 0…300 V; Error <0.1% reading + 0.1% range guaranteed at 0...20 A; |
|
Resolution |
1mA; 1 mV |
|
Aux DC Supply |
||
Range |
0...300V/0.6A |
|
Binary inputs |
||
Number |
8 pairs |
|
Compatible Voltage |
10V ... 250V DC |
|
Binary outputs |
||
Number |
4 Pairs |
|
Capacity |
250V/3A (AC/DC) |
|
Synchronization |
||
Synchronization mode |
GPS |
|
Harmonic |
||
Harmonic overlap times |
2 ... 9 times |
|
Power supply |
||
Nominal input voltage |
220V±20% VAC, 1-phase |
|
Power |
1000VA |
|
Nominal frequency |
50±10% Hz |
|
Environmental conditions |
||
Operation temperature |
-5°C ... 55 °C |
|
Storage temperature |
-20°C ... 75 °C |
|
Humidity range |
5% ... 90 %, non-condensing |
|
Weight |
20KG |
|
Dimensions |
460(D)×140 (W)×360 (H) mm |
|
Interface |
RJ45 , USB, VGA |
Main Series Relay Tester List
K68 series |
K68 |
3x35A, 4x130V, 5 function modules, Ethernet, TFT LCD, WinCE |
K68i |
3x35A, 4x300V, 5 function modules, Ethernet, TFT LCD, WinCE |
Major Functions
Items |
IEEE(R) No. |
Overcurrent relays |
51/76 |
Inverse time overcurrent relays |
50 |
Undercurrent relays |
37 |
Ground fault relays |
50 |
Directional overcurrent relays |
67 |
Directional ground fault relays |
67N |
Overvoltage relays |
59 |
Undervoltage relays |
27 |
Directional voltage relays |
91 |
Directional power relays |
32 |
Power factor relays |
55 |
Distance protection equipment (phase by phase) |
21 |
Automatic reclosing devices |
79 |
Tripping relays |
94 |
Voltage regulating relays |
|
Overimpedance relays, Z> |
|
Underimpedance relays, Z |
|
Time-delay relays |
|