Send Message
Home ProductsProtection Relay Testing

K31 Series Relay Protection Tester Secondary Injection Test Equipment K3163i

Certification
China Kingsine Electric Automation Co., Ltd. certification
China Kingsine Electric Automation Co., Ltd. certification
Customer Reviews
KINGSINE is a reliable company with good quality products, reasonable price and perfect service.

—— Mike Moeller

To do business with KINGSINE is a satisfying experience,they provide Prompt reply and best Technical support.

—— Joseph

I'm Online Chat Now

K31 Series Relay Protection Tester Secondary Injection Test Equipment K3163i

K31 Series Relay Protection Tester Secondary Injection Test Equipment K3163i
K31 Series Relay Protection Tester Secondary Injection Test Equipment K3163i

Large Image :  K31 Series Relay Protection Tester Secondary Injection Test Equipment K3163i

Product Details:
Place of Origin: China
Brand Name: KINGSINE
Certification: ISO9001,CE
Model Number: K3163i
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Delivery Time: 15 working days
Payment Terms: T/T in advance,L/C
Supply Ability: 50 sets/month
Detailed Product Description
High Light:

K31 Series Relay Protection Tester

,

Secondary Injection Test Equipment K3163i 

All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+4V analog channels output, Inbuilt

 

GPS and IRIG-B, and other advance functions.

 

 

         ◆ Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc

 

         ◆100/1000Mbit Fiber port for SMV and GOOSE simulations

       

         ◆6x35A & 4x310V independent high burden output channels

 

         ◆13 channels independent low-level signal outputs

 

         ◆ AC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)

 

         ◆ Transducer calibration (0.02 class)

 

         ◆ Energy meter calibration (Mechanical & Electronic meters)

 

         ◆ Transient play back up to 3KHz

 

         ◆ Lightweight, <18Kg

 

         ◆ Fully function KRT software testing modules

 

         ◆ 3-Years guarantee of free repair and life-long maintenance

 

         ◆ Free software upgrade

   

 

Ordering Ref.

 

Model Current Outputs Voltage Outputs
K3166 6×35A @ 450VA max / 3×70A @ 850VA max 7×130V @ 75VA max
K3166i 6×35A @ 450VA max / 3×70A @ 850VA max 7×310V @ 90VA max
K3163 6×35A @ 450VA max / 3×70A @ 850VA max 4×130V @ 75VA max
K3163i 6×35A @ 450VA max / 3×70A @ 850VA max 4×310V @ 124VA max
K3130 3×35A @ 450VA max 4×130V @ 75VA max
K3130i 3×35A @ 450VA max 4×310V @ 124VA max

 

   

Able of what K31 series can test

   
Items ANSI® No.
IEC61850 numerical IEDs relay & merge unit  
Distance protection relay 21
Synchronising or synchronism-check relays 25
Undervoltage relays 27
Directional Power relays 32
Undercurrent or underpower relays 37
Negative sequence overcurrent relays 46
Overcurrent/ground fault relays 50
Inverse time overcurrent/ground fault relays 51
Power factor relays 55
Overvoltage relays 59
Voltage or current balance relays 60
Directional overcurrent relays 67
Directional ground fault relays 67N
DC overcurrent relays 76
Phase-angle measuring or out-of-step protection relays 78
Automatic reclosing devices 79
Frequency relays 81
Motor overload protection relays 86
Differential protection relays 87
Directional voltage relays 91
Voltage and power directional relays 92
Tripping relays 94
Voltage regulating relays  
Overimpedance relays, Z>  
Underimpedance relays, Z  
Time-delay relays  

 

 

 

   Characteristic

 

 

◆ 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous

 

     control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to

 

     20x harmonics.

 

◆ Variable battery simulator, DC 0-350V, 140Watts max.

 

◆ 13 Low-level channels outputs up to 8Vac/10Vdc max.

 

◆ 0-600V / 0-5A AC/DC measurement in 0.1 class.

 

◆ Graphical test modules and templates for testing of various relays

 

◆ Quick relay testing facility in Manual mode

 

◆ Shot/Search/Check, Point & Click testing

 

◆ RIO/XRIO import & export facility

 

◆ Switch on to fault test(SOTF)

 

◆ Power system model for dynamic testing

 

◆ Inbuilt GPS and IRIG-B sync end-to-end testing

 

◆ Online Vector display

 

◆ Automatic test results assume

 

◆ Automatic test report creation

 

◆ Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection

    

 

 

Parameters

 

 Voltage Outputs
 Output Range & Power  4×310 V ac (L-N)  124 VA max each
 2×620 V ac (L-L)  248 VA max each
 3×350 V dc (L-N)  140 W max each
 Accuracy

 

 AC: <0.03%Rd+0.01Rg Typ.

 

 <0.07%Rd+0.03Rg Guar.

 

 DC: ±10mV @ <5V, ±0.5% @ ≥5V
 Resolution  1mV
 Distortion  <0.05%Typ. / <0.1% Guar.
 Current Outputs
 Output Range & Power  6×35A ac (L-N)  450 VA max each
 3×70A ac (2L-N)  850 VA max each
 1×100A ac (6L-N)  1200 VA max
 3×20A dc (L-N)  300W max each
 Accuracy

 

 AC: <0.05%Rd+0.02Rg Typ.

 

 <0.15%Rd+0.05Rg Guar.

 

 DC: ±5mA @ <1A, ±0.5% @ ≥1A
 Resolution  1mA
 Distortion  <0.05%Typ. / <0.1% Guar.
 13 Low-Level Channel Outputs
 Quantity  13 Channels, 16 pin aviation socket
 Voltage Outputs Range  AC 0~8V, DC 0~10V
 Current Outputs Range  Nominal 2mA, 10mA max transient
 Output Power  ≥0.5VA
 Accuracy

 

 (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.

 

 (0.8~8 Vrms): <0.02% Typ. / <0.05% Guar.

 

 Resolution  0.25mV
 Distortion(THD%)  <0.05% Typ. / <0.1% Guar.
 Frequency & Phase Angle
 Frequency Range  DC~1KHz, 3KHz transient
 Frequency Accuracy  ±1ppm
 Frequency Resolution  0.001 Hz
 Phase Range  -360°~360°
 Phase Accuracy  <0.05° Typ. / <0.1° Guar. 50/60Hz
 Phase Resolution  0.001°
 IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)
 Fiber Ports

 

 2 x 100Base-FX Full Duplex, LC type

 

 (Optional to 10/100Mbit, Ethernet RJ45 type)

 

 Fiber Type  62.5/125um (Multiple optical fiber, Orange Red)
 Wavelength  1310nm
 Transmit Distance  >1Km
 Indicator

 

 Spd Green(light): Valid connection

 

 Link/Act Yellow(Blinking): Data exchanging

 

 Note: All hardware of this module are ready for active
 Aux. DC Voltage Source (Battery simulator)
 Range  0~350V @ 140W max
 Accuracy  0.5%Rg Guar.
 Binary Input
 Quantity  8pairs
 Type  wet/dry, measurement
 Threshold  10~600Vdc or potential free, Programmable
 Time resolution  100us
 Debounce time  0~25ms (Software Controlled)
 Time range  Infinite
 Time errors  ±1ms @ 0.001~1s, ±0.1% @ >1s
 Galvanic isolation  4 isolated with each 2 pairs
 Binary Output (Relay Type)
 Quantity   4pairs
 Type

 

 Potential free relay contacts, software  controlled

 

 Break Capacity AC  Vmax: 400Vac / Imax:8A / Pmax:2500VA
 Break Capacity DC  Vmax: 300Vdc / Imax:5A / Pmax:150W
 Binary Output (Semiconductor Type)
 Quantity  4pairs
 Type:  Open-collector, 14 pin Aviation socket
 Break Capacity DC

 

 5~15Vdc / 5mA, 10mA max

 

 AC not permit

 

 Response time:  100us
 Synchronization
 Synchronization Mode 

 

 GPS, SMA type antenna connector

 

 IRIG-B, FT3

 

 IEEE1588

 

 Power supply & Environment
 Nominal Input Voltage  100~240Vac
 Permissible Input Voltage  85~264Vac, 125~350VDC
 Nominal Frequency  50/60Hz
 Permissible Frequency  45Hz~65Hz
 Power Consumption  1500 VA max
 Connection Type  Standard AC socket 60320
 Operating Temperature  -10℃~55℃
 Storage Temperature  -20℃~70℃
 Humidity  <95%RH, non-condensing
 Others
 PC Connection  RJ45 Ethernet, 10/100/1000M
 Grounding Terminal  4mm banana socket
 Weight  18 Kg
 Dimensions(W x D x H)  468×375×164(mm)
 

 

 

Additional Information (Optional Modules)

 

 DC Measurement Input (Transducer calibrator)
 Voltage Input  Range  0~±10V dc
 Max Input  ±11V dc
 Accuracy  <0.02% rg Typ. <0.05% rg Guar.
 Input Impedance  1Mohm
 Current Input  Range  0~±1mA / 1~±20mA, auto range
 Max Input  600mA
 Accuracy  <0.02% rg Typ. <0.05% rg Guar.
 Input Impedance  15 ohm
 AC/DC Measurement Input (Standard meter)
 Input Quantity  8 channels (blend with binary input pairs)
 Voltage range  0~600Vrms (Rg:0.1V,1V, 10V, 60V, 600V)
 Voltage accuracy  <0.1% Rg
 Current range  0~5Arms(clamp input)
 Current accuracy  <0.1% Rg
 Sample rate 10KHz
 Input impedance  600KΩ
 Frequency range  45~65Hz, Accuracy < 0.01Hz
 Phase accuracy  0~360°, <0.2° Typ.
 Transient Recorder
 Input Quantity  8 input channels (blend with binary input pairs)
 Recorder time  Max 50 Sec.
 Energy Meter Calibration
 Sensor Usage  Mechanical meters / Electronic meters
 Sensor Output  High lever:>4.5V, Low level:<0.2V
 Pulse Input  1 pulse input port
 Pulse Range  500KHz pulse input Max.
 Pulse Output  1 Transistor output, Open-collector, 5-15Vdc/5mA
 

 

Contact Details
Kingsine Electric Automation Co., Ltd.

Contact Person: Amy

Tel: +8613603051120

Send your inquiry directly to us (0 / 3000)