Brand Name: | KINGSINE |
Model Number: | PMC200S |
MOQ: | 1 set |
Price: | Negotiation |
Delivery Time: | 7 working days |
Payment Terms: | T/T in advance ,L/C |
1.Introduction
PMC200 Power Parameter Tester is widely used for energy management system, substation automation, distribution network automation, subdistrict power distribution, industrial automation, intelligent building, intelligent switchboard, switch cabinet, etc. It integrates the digitization, intellectualization and networking together, to replace the traditional equipments such as electric quantity transducer, numeric display instrument, data acquisition unit and recorder analyzer, etc. The multi-purpose lows the cost, and the simple wire connection simplifies the testing.
2.Functions and Features
Parameter Measurement | Current |
Voltage | |
Active/Reactive/Apparent Power | |
Power Factor | |
Frequency | |
Phase and Neutral Line | |
Wire Line and Phase Line | |
3 Phases and Single Phase | |
3 Phases and Single Phase | |
Energy Measurement | Input/Output Active Energy |
Input/Output Reactive Energy | |
Apparent Energy | |
1 Channel Pulse Output | |
1 Channel Pulse Output | |
Demand Statistics | Current |
Active/Reactive/Apparent Power | |
Current Value and Max. | |
Current Value and Max. | |
Maximum and Minimum | Record the maximum, minimum and time of all measurement parameters |
Restoration Rate | 8 Restoration Stages; 4 Restoration Rate can be set |
Power Quality | Harmonic Distortion |
31 times Harmonic Analysis | |
Current and Voltage | |
Current and Voltage | |
Communication Protocol | MODBUS-RTU |
Display | STN LCD Display with big screen |
Real-Time Clock | |
Year/Month/ Day/Hour/Minute/Second | |
Relay Output Module | 2 Channels Relay Output |
Programmable Alarm Setting of exceeding the limit | |
Remote Control | |
Analog Input and Output Module | 1 Channel Analog Input Measurement for 4-20mA DC |
1 Channel Analog Input Measurement for 0-5V DC | |
2 Channels Analog Output for 4-20mA DC |
3. Technical Parameter
Electrical characteristics | ||
Measure Type | 3P3W AC system, 3P4W AC system | |
Sampling rate | 128 points per cycle | |
Data refresh rate | 1S | |
Measure accuracy | Current | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
Active Energy | 0.5S | |
Reactive Energy | 1.0S | |
DC input(AI) | 0.5% FS | |
DC output(AO) | 0.5% FS | |
Input voltage characteristics | Measure Voltage | 3 *220/380V(Directly input) |
3 * 57.7/100V(PT secondary side) | ||
Allowed overload capability | 1.2 times / continuous | |
input resistance | 300KΩ | |
Input current characteristics | Measure current | 5A (CT Secondary side)Or 1A (CT Secondary side) |
Allowed overload capability | 1.2 times / continuous | |
input resistance | <0.1Ω | |
Binary input | Working voltage | 12~24 VDC |
input resistance | 12KΩ | |
Isolation voltage | 2KV | |
Relay Output | Node type | Mechanical contact |
Node capability | 220 VAC/5A,30 VDC/5A | |
4-20mA DC input measurement | Measure current | 4-20mA |
Allowed overload capability | 1.2 times / continuous | |
input resistance | 10Ω | |
Isolation voltage | 2KV | |
0-5V DC input measurement | Measure Voltage | 0-5V |
Allowed overload capability | 1.2 times / continuous | |
input resistance | 12.5KΩ | |
Isolation voltage | 2KV | |
4-20mA DC output | Open-circuit Voltage | 15VDC |
Load capability | ≤600Ω | |
Isolation voltage | 2KV | |
Power supply | AC | 100~240 VAC/45-65Hz |
DC | 100~375 VDC | |
Power consumption | < 3W | |
Mechanical performance | ||
Weight | 0.5kg | |
IP Protection Level | Meter Panel IP52, Meter Host IP30 | |
Dimension | Host | 96 X 96 X 72 mm |
Host+modules | 96 X 96 X 120 mm | |
Working temperature | Display screen | -20~70℃ |
Meter | -25~70℃ | |
storage temperature | Meter+display screen | -40~85℃ |
Relative humidity | 5% - 90%RH, No condensation | |
EMC | ||
Antistatic discharge interference | IEC 61000-4-2,Level 4 | |
Anti-fast transient group pulse | IEC 61000-4-4,Level 4 | |
Anti-surge | IEC 61000-4-5,Level 3 | |
Resistance to power frequency magnetic field | IEC 61000-4-8,Level 3 | |
Electrical insulation performance | ||
Insulation resistance | GB/T13729,>50MΩ | |
Power frequency withstand voltage | GB/T13729,AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
PMC200S selection guide
Model specification:PMC200S-①-②-③-④-⑤ | |
①Model code: | |
1 | 57.7/100V Rated measurement voltage,5A Rated measurement current. |
2 | 57.7/100V Rated measurement voltage,1A Rated measurement current. |
3 | 220/380V Rated measurement voltage,5A Rated measurement current. |
4 | 220/380V Rated measurement voltage,1A Rated measurement current. |
②Model code: | |
1 | Power supply:85~264 VAC/45-65Hz,100~300 VDC . |
③Model code: | |
0 | Without DI |
4 | 4 Channels DI |
④Model code: | |
0 | Without relay output |
1 | Optional 1 channel relay output(RL1+,RL1- port) |
2 | Optional 2 channels relay output |
⑤Model code: | |
ab |
ab is a 2 integer,a means AI01 port optional for AI/AO modules, b means AI02 port optional for AI/AO 0 –none 1 - 0-5V DC analog input measure(AI) 2 - 4-20mA DC analog input measure(AI) 3 - 4-20mA DC analog output(AO) For example: ab = 00,Means AI 01 port is not equipped with AI/AO module, AI02 port is not equipped with AI/AO module ab = 12,Means AI01 port is equipped with 0-5V DC analog input measure AI/AO module, AI02 port is equipped with 4-20mA DC analog input measure AI/AO module |
For example: Order model: PMC200S-3-1-4-2-12
Means PMC200S rated measure 220V/380V,5A, working power supply as 85-264VAC/45-65HZ,Optional with 4channels binary input(DI), 2 channels relay output; 1 channel 0-5V DC analog input measure(AI01 port),1 channel 4-20mA DC analog input measure(AI02 port)
Brand Name: | KINGSINE |
Model Number: | PMC200S |
MOQ: | 1 set |
Price: | Negotiation |
Payment Terms: | T/T in advance ,L/C |
1.Introduction
PMC200 Power Parameter Tester is widely used for energy management system, substation automation, distribution network automation, subdistrict power distribution, industrial automation, intelligent building, intelligent switchboard, switch cabinet, etc. It integrates the digitization, intellectualization and networking together, to replace the traditional equipments such as electric quantity transducer, numeric display instrument, data acquisition unit and recorder analyzer, etc. The multi-purpose lows the cost, and the simple wire connection simplifies the testing.
2.Functions and Features
Parameter Measurement | Current |
Voltage | |
Active/Reactive/Apparent Power | |
Power Factor | |
Frequency | |
Phase and Neutral Line | |
Wire Line and Phase Line | |
3 Phases and Single Phase | |
3 Phases and Single Phase | |
Energy Measurement | Input/Output Active Energy |
Input/Output Reactive Energy | |
Apparent Energy | |
1 Channel Pulse Output | |
1 Channel Pulse Output | |
Demand Statistics | Current |
Active/Reactive/Apparent Power | |
Current Value and Max. | |
Current Value and Max. | |
Maximum and Minimum | Record the maximum, minimum and time of all measurement parameters |
Restoration Rate | 8 Restoration Stages; 4 Restoration Rate can be set |
Power Quality | Harmonic Distortion |
31 times Harmonic Analysis | |
Current and Voltage | |
Current and Voltage | |
Communication Protocol | MODBUS-RTU |
Display | STN LCD Display with big screen |
Real-Time Clock | |
Year/Month/ Day/Hour/Minute/Second | |
Relay Output Module | 2 Channels Relay Output |
Programmable Alarm Setting of exceeding the limit | |
Remote Control | |
Analog Input and Output Module | 1 Channel Analog Input Measurement for 4-20mA DC |
1 Channel Analog Input Measurement for 0-5V DC | |
2 Channels Analog Output for 4-20mA DC |
3. Technical Parameter
Electrical characteristics | ||
Measure Type | 3P3W AC system, 3P4W AC system | |
Sampling rate | 128 points per cycle | |
Data refresh rate | 1S | |
Measure accuracy | Current | ±0.2%FS |
Voltage | ±0.2%FS | |
Power | 0.5S | |
Frequency | ±0.001Hz | |
Active Energy | 0.5S | |
Reactive Energy | 1.0S | |
DC input(AI) | 0.5% FS | |
DC output(AO) | 0.5% FS | |
Input voltage characteristics | Measure Voltage | 3 *220/380V(Directly input) |
3 * 57.7/100V(PT secondary side) | ||
Allowed overload capability | 1.2 times / continuous | |
input resistance | 300KΩ | |
Input current characteristics | Measure current | 5A (CT Secondary side)Or 1A (CT Secondary side) |
Allowed overload capability | 1.2 times / continuous | |
input resistance | <0.1Ω | |
Binary input | Working voltage | 12~24 VDC |
input resistance | 12KΩ | |
Isolation voltage | 2KV | |
Relay Output | Node type | Mechanical contact |
Node capability | 220 VAC/5A,30 VDC/5A | |
4-20mA DC input measurement | Measure current | 4-20mA |
Allowed overload capability | 1.2 times / continuous | |
input resistance | 10Ω | |
Isolation voltage | 2KV | |
0-5V DC input measurement | Measure Voltage | 0-5V |
Allowed overload capability | 1.2 times / continuous | |
input resistance | 12.5KΩ | |
Isolation voltage | 2KV | |
4-20mA DC output | Open-circuit Voltage | 15VDC |
Load capability | ≤600Ω | |
Isolation voltage | 2KV | |
Power supply | AC | 100~240 VAC/45-65Hz |
DC | 100~375 VDC | |
Power consumption | < 3W | |
Mechanical performance | ||
Weight | 0.5kg | |
IP Protection Level | Meter Panel IP52, Meter Host IP30 | |
Dimension | Host | 96 X 96 X 72 mm |
Host+modules | 96 X 96 X 120 mm | |
Working temperature | Display screen | -20~70℃ |
Meter | -25~70℃ | |
storage temperature | Meter+display screen | -40~85℃ |
Relative humidity | 5% - 90%RH, No condensation | |
EMC | ||
Antistatic discharge interference | IEC 61000-4-2,Level 4 | |
Anti-fast transient group pulse | IEC 61000-4-4,Level 4 | |
Anti-surge | IEC 61000-4-5,Level 3 | |
Resistance to power frequency magnetic field | IEC 61000-4-8,Level 3 | |
Electrical insulation performance | ||
Insulation resistance | GB/T13729,>50MΩ | |
Power frequency withstand voltage | GB/T13729,AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729,5KV,1.2/50us |
PMC200S selection guide
Model specification:PMC200S-①-②-③-④-⑤ | |
①Model code: | |
1 | 57.7/100V Rated measurement voltage,5A Rated measurement current. |
2 | 57.7/100V Rated measurement voltage,1A Rated measurement current. |
3 | 220/380V Rated measurement voltage,5A Rated measurement current. |
4 | 220/380V Rated measurement voltage,1A Rated measurement current. |
②Model code: | |
1 | Power supply:85~264 VAC/45-65Hz,100~300 VDC . |
③Model code: | |
0 | Without DI |
4 | 4 Channels DI |
④Model code: | |
0 | Without relay output |
1 | Optional 1 channel relay output(RL1+,RL1- port) |
2 | Optional 2 channels relay output |
⑤Model code: | |
ab |
ab is a 2 integer,a means AI01 port optional for AI/AO modules, b means AI02 port optional for AI/AO 0 –none 1 - 0-5V DC analog input measure(AI) 2 - 4-20mA DC analog input measure(AI) 3 - 4-20mA DC analog output(AO) For example: ab = 00,Means AI 01 port is not equipped with AI/AO module, AI02 port is not equipped with AI/AO module ab = 12,Means AI01 port is equipped with 0-5V DC analog input measure AI/AO module, AI02 port is equipped with 4-20mA DC analog input measure AI/AO module |
For example: Order model: PMC200S-3-1-4-2-12
Means PMC200S rated measure 220V/380V,5A, working power supply as 85-264VAC/45-65HZ,Optional with 4channels binary input(DI), 2 channels relay output; 1 channel 0-5V DC analog input measure(AI01 port),1 channel 4-20mA DC analog input measure(AI02 port)