Send Message
Home ProductsRelay Test System

IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900

Certification
China Kingsine Electric Automation Co., Ltd. certification
China Kingsine Electric Automation Co., Ltd. certification
Customer Reviews
KINGSINE is a reliable company with good quality products, reasonable price and perfect service.

—— Mike Moeller

To do business with KINGSINE is a satisfying experience,they provide Prompt reply and best Technical support.

—— Joseph

I'm Online Chat Now

IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900

IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900
IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900 IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900

Large Image :  IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900

Product Details:
Place of Origin: China
Brand Name: Kingsine
Certification: ISO9001,CE
Model Number: KF900
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Delivery Time: 15 working days
Payment Terms: T/T in advance ,L/C
Supply Ability: 50 sets/ month
Detailed Product Description
High Light:

Optical Digital Relay Test System

,

IEC61850-9-1 electrical relay testing

,

KF900 Digital Relay Test System

    

IEC61850-9-1 Optical Digital Relay Test System / Transient Test KF900

1.Easy test
2.operation menu, Simple operation
3.IEC61850-9-1 / IEC61850-9-2  standard
4.Rated Frequency:50Hz

 

* With four fiber Ethernet interfaces and 3-way FT3 dedicated output interface

* In accordance with IEC61850-9-1 or IEC61850-9-2 frame format and send samples FT3 frame format or publish / subscribe GOOSE messages,

*The output sample value or GOOSE can be freely defined,

* Has 12 channels of analog output of weak signal, to achieve a variety of protection relay, monitoring and control devices, intelligent operation box testing.

Function Features

Provide fully test solutions to various IEC61850 relay protective devices & automation devices for all power users.
Provide 4 pairs of 100Base-FX optical interface, 3(FT3)ST optical out, support EC61850-9-1, EC61850-9-2, EC6004-7/8(FT3)and Goose optical digital message output test
Conventional analog binary input procession is compatible, providing 8 pairs analog binary input & 4 pairs binary output
Provide 1 RG-B/PPS interface, can access RG-B or PPS time signal which synchronize with GPS synchronous clock.

 Technical Parameter

Binary Input

 

 

No.

 

8 pairs

Input Characteristic

0V~250V(DC) or no contanct (identified automatically)

sample Frequency     

10kHz

Time Resolution

100μs

Max measuring time  

1.50×105 s

Timing Error  

  ±1ms (0.001s~1s)

±0.1%(1s~1.50×105 s) 

Set Range of Debounce Time( set by software)

  0ms~25ms

Electric Isolation

8 pairs input electric isolation

Threshold Impedance Parameter(no contacts)         

5 kΩ…13kΩ

 

 Sychronization Interface (GPS)

 

 

KSGGPS satellite sychronization device)is optional;

B code (RS485) sychronization interface

Binary Output

 

No. 

4 pairs

Type

no contants and no pole,  controlled by software

AC capacity  

Vmax:250V (DC)/Imax:3A

 DC  capacity  

 Vmax:250V (DC)/Imax:1A

Power Supply

 

Rated Voltage

220V(AC)

Allowed Voltage

100V~240V(AC)

Rated Frequency

50Hz

Allowed Frequency

40~60Hz

Current

1A (max.)

FT3 Interface 

 

Using Standard

IEC60044-7/8

Terminal NO.

3 pairs

Interface Type

ST

Wave Length

850nm

Optical Fiber Type

62.5/125μm, multi-mode

Transmission Distance

1km

Ethernet Communication Interface

 

Type

10/100 Base-TX(10/100 Mbit,  twisted pair/ auto crossed)

Port No.

1 pairs

Interface Type

RJ45

Cable Type

5 pairs twisted pair

State Indication

LED green(light):effective connection

LED yellow(flicker): data communication

Fiber Optic Communication Interface

 

Type

100Base-FX(100Mbit, fiber optic, full-duplex)

Port No.

4 pairs

Interface Type

SC

Cable Type

62.5/125μm(multimode fiber orange)

Wave Length

1300nm

Transmission Distance

> 1Km

State Indication

SPD green(light):effective connection

Link/AcT yellow(flicker): data communication

Operational Environment

 

Operational Temperature

-10℃~+50℃

Storage& Transportation Temperature

-20℃~+70℃

Humidity

5~90% relative humidity,  no condensation

 

 